pp. 423-438
S&M540 Research Paper of Special Issue Published: 2003 Indirect Competitive Immunoassay for Bisphenol A, Based on a Surface Plasmon Resonance Sensor [PDF] Nobuaki Soh, Tomomi Watanabe, Yasukazu Asano and Toshihiko Imato (Received November 10, 2003; Accepted November 29, 2003) Keywords: surface plasmon resonance (SPR), bisphenol A (BPA), endocrine-disrupting chemicals (EDCs), immunosensor, inhibition method
A method for the determination of bisphenol A (BPA), a representative endocrine- disrupting chemical, was developed using a surface plasmon resonance (SPR) sensor. The method is based on an indirect competitive immunoassay, where a BPA sample containing an anti-BPA antibody is introduced into the SPR sensor system. A sensor chip immobi- lized with a 2AET layer/ BPA layer membrane was prepared by depositing 2-aminoethanthiol (2AET) on a gold film on the sensor chip, followed by reacting the 2AET layer with esterified BPA. The resulting sensor chip was placed into the SPR sensor of a flow system, which consisted of a syringe pump and an injector. The sensor response, in the form of a resonance angle shift, was measured as a function of time before and after injecting different concentrations of BPA in a sample solution that contained the anti-BPA antibody at a constant concentration. In order to estimate the affinity constant of the anti-BPA antibody to BPA, which was immobilized on the sensor chip, the SPR angle shift was first measured by injecting an anti-BPA antibody solution at different concentrations into the SPR system. The affinity constant of the anti-BPA antibody to BPA immobilized on the sensor chip (K1) was calculated to be 9.3 105 M–1 from the SPR angle shift data, assuming a Langmuir adsorption isotherm. BPA sample solutions (1–100 ppb) containing 40 ppm anti-BPA antibody were then injected into the SPR system, and the SPR angle shift was determined for each of the sample solutions. A conventional sigmoidal calibration curve, which was typically observed in a competition immunoassay, was obtained when the SPR angle shift was plotted against the BPA concentration. The affinity constant of the anti- BPA antibody to the free BPA (K2) in the sample solution was estimated to be 1 107 M–1 by fitting the observed calibration curve to the theoretical one for a competitive inhibition assay. The BPA detection limit of the method was determined to be approximately 10 ppb.
Corresponding author: Toshihiko ImatoCite this article Nobuaki Soh, Tomomi Watanabe, Yasukazu Asano and Toshihiko Imato, Indirect Competitive Immunoassay for Bisphenol A, Based on a Surface Plasmon Resonance Sensor, Sens. Mater., Vol. 15, No. 8, 2003, p. 423-438. |