pp. 45-53
S&M704 Research Paper https://doi.org/10.18494/SAM.2008.507 Published: February 29, 2008 Nickel Microneedles Fabricated by Sequential Copper and Nickel Electroless Plating and Copper Chemical Wet Etching [PDF] Phill Gu Jung, Tae Won Lee, Dong Joon Oh, Sung Jin Hwang, Im Deok Jung, Sang Min Lee and Jong Soo Ko (Received July 30, 2007; Accepted October 16, 2007) Keywords: microneedle, electroless plating, chemical etching
Nickel microneedles have been fabricated by a sequential process of electroless copper and nickel plating and copper wet chemical etching. An electroless plating solution was injected using an external syringe pump and made to flow through the inside of a copper base tube. The temperature gradient along the length of the copper base tube brings about different plating thicknesses along its length, resulting in a wide inlet and a sharp end with a microaperture. The diameter of the microaperture could be readily controlled by plating time such that microneedles with various diameters could be easily acquired. To verify their applicability, the fabricated microneedles have been applied to a probe for cell capturing and to a needle for microdispensing.
Corresponding author: Jong Soo KoCite this article Phill Gu Jung, Tae Won Lee, Dong Joon Oh, Sung Jin Hwang, Im Deok Jung, Sang Min Lee and Jong Soo Ko, Nickel Microneedles Fabricated by Sequential Copper and Nickel Electroless Plating and Copper Chemical Wet Etching, Sens. Mater., Vol. 20, No. 1, 2008, p. 45-53. |